Power requirements
Terminal block connector input
voltage/current
24 VAC (50 Hz–60 Hz) or 24 VDC /
15A
Power adapter input voltage/current 19.5 VDC / 6.67A
Battery connector port 12VDC / 15A
Environmental requirements
Ingress Protection Rating IP50
Temperature range:
Operating (with a maximum
temperature gradation of 15°C
per hour)
• -30°C to 70°C (-22°F to 158°F)
when connected to a 24V AC/DC
power source.
• -30°C to 40°C (-22°F to 104°F)
when connected to a power
adapter or battery.
NOTE: The maximum operating
temperature is derated 1°C/
305m(1000ft) above sea level
altitude.
Non-operating -40°C to 70 °C (-40°F to 158°F)
Relative humidity (maximum):
Operating (with maximum
humidity gradation of 10% per
hour)
10% to 90% (non-condensing)
Non-operating ((with maximum
humidity gradation of 10% per
hour)
5% to 95% (non-condensing)
Altitude (maximum, unpressurized):
Operating -15.2m to 5000m (-50ft to 16,404ft)
NOTE: The maximum operating
temperature is derated 1°C/
305m (1000ft) above sea level
altitude.
49