Environmental requirements
Operating (with a maximum
temperature gradation of 15°C
(59°F) per hour)
Dell Edge Gateway 5000: 0°C to
45°C (32°F to 113°F)
Dell Edge Gateway 5100: -30°C
to 70°C (-22°F to 158°F)
NOTE: The maximum operating
temperature is derated 1°C/
305m (1000ft) above sea level
altitude.
NOTE: The maximum operating
temperature is derated 18°C
(32.4°F) under direct solar
thermal load.
Non-operating (with a
maximum temperature
gradation of 15°C (59°F) per
hour)
-40°C to 70°C (-40°F to 158 °F)
Relative humidity (maximum):
Operating (with maximum
humidity gradation of 10% per
hour)
10% to 90% (non-condensing)
Non-operating (with maximum
humidity gradation of 10% per
hour)
5% to 95% (non-condensing)
Altitude (maximum, unpressurized):
Operating -15.2m to 5000m (-50ft to 16,404ft)
NOTE: The maximum operating
temperature is derated 1°C/
305m (1000ft) above sea level
altitude.
Storage -15.2m to 10,668m (-50ft to
35,000ft)