60 | System Specifications
www.dell.com | support.dell.com
Environmental Parameters
Power Supplies System Power Requirements
Table D-1. AC Power System Specifications
Table D-2. DC Power System Specifications
Parameter Specifications
Operating:
Temperature 40° to 105°F (5° to 40°C)
Maximum altitude No performance degradation to 10,000 feet (3,048 meters)
Relative humidity 5 to 85 percent, noncondensing
Non-operating:
Temperature -40° to 158°F (-40° to 70°C)
Maximum altitude 15,000 feet (4,572 meters)
Relative humidity 5 to 95 percent, noncondensing
Parameter Specifications
Nominal Input Voltage 100 - 240 VAC 50/60 Hz
Maximum AC Power Supply Input Current (based on 800W
output for 100/120V line and 1200W output for 200/240V
line.)
7.4 A @ 100 VAC per AC Power Supply
6.2 A @ 120 VAC per AC Power Supply
5.2 A @ 200 VAC per AC Power Supply
4.3 A @ 240 VAC per AC Power Supply
Maximum System Power Input 2.2 KVA @ 100/120 VAC
2.0 KVA @ 200/240 VAC
Maximum System Power Consumption 2,149 W @100/120 VAC
2,000 W @ 200/240 VAC
Maximum Thermal Output (2,049 W) for 100/120 V 6,989 BTU/hour
Maximum Thermal Output (1,900 W) for 200/240 V 6,483 BTU/hour
Parameter Specifications
Nominal Input Voltage -44 to 60 VDC
Maximum Current Draw (per DC PEM) 60 A
Maximum System Power Consumption 1,740 W
Maximum Thermal Output (1,640 W) 5,596 BTU/hour