must reenter the system configuration information and reset the options each time the sled boots until
you replace the battery.
Steps
1. Reenter the time and date through the System Setup.
2. Turn off the sled using the operating system commands or the CMC.
3. Remove the sled from the enclosure for at least one hour.
4. Install the sled in the enclosure.
5. Turn on the sled.
6. Enter the System Setup.
If the date and time are not correct in the System Setup, replace the battery. If the problem is not
resolved by replacing the battery, see the Getting help section.
NOTE: If the sled is turned off for long periods of time (for weeks or months), the NVRAM may
lose its system configuration information. This situation is caused by a defective battery.
NOTE: Some software may cause the sled’s time to speed up or slow down. If the sled operates
normally except for the time maintained by the System Setup, the problem may be caused by a
software rather than by a defective battery.
Related Links
Getting help