Table 11. PSU specifications (continued)
PSU Class Heat
di
ssip
ation
(maxi
mum)
Frequenc
y
Voltage AC DC Current
High line
200–240 V
Low line
100–120 V
800 W Mixed
Mode
Platinu
m
3000
BTU/
hr
50/60 Hz
100 - 240 V,
autoranging
800 W 800 W N/A 9.2 A - 4.7 A
N/A 3000
BTU/
hr
N/A
240 V DC N/A N/A 800 W 3.8 A
1100 W DC N/A 4265
BTU/
hr
N/A
-48 VDC – -60
VDC
N/A N/A 1100 W 27 A
1100 W
Mixed Mode
Titaniu
m
4125
BTU/
hr
50/60 Hz
100 - 240 V 1100 W 1050 W N/A 12 A - 6.3 A
N/A 4125
BTU/
hr
N/A
240 V DC N/A N/A 1100 W 5.2 A
1400 W
Mixed Mode
Platinu
m
5250
BTU/
hr
50/60 Hz
100 - 240 V 1400 W 1050 W N/A 12 A - 8 A
N/A 5250
BTU/
hr
N/A
240 V DC N/A N/A 1400 W 6.6 A
1800 W
Mixed Mode
Titaniu
m
6610
BTU/
hr
50/60 Hz 200–240 V AC 1800 W NA NA 10 A
NA 6610
BTU/
hr
NA 240 V DC NA NA 1800 W 8.2 A
2400 W
Mixed Mode
Platinu
m
9000
BTU/
hr
50/60 Hz
100 - 240 V,
autoranging
2400 W 1400 W N/A 16 A - 13.5 A
N/A 9000
BTU/
hr
N/A
240 V DC N/A N/A 2400 W 11.2 A
NOTE: This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240
V.
NOTE: If a system with AC 1400W/1100W PSUs operates at low line 100-120 V AC, then the power rating per PSU is
derated to 1050W.
NOTE: If a system with AC 2400 W PSUs operates at low line 100-120 V AC, then the power rating per PSU is derated to
1400W.
NOTE: Heat dissipation is calculated using the PSU wattage rating.
NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system
power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.
Technical specifications 35