PowerVault (Dell MD1400) Setup Guide
Series 6 Physical Hosts
Series 6 - R640
The following figure shows Series 6 - R640 host (port 0) connected to PowerVault (port 1 in
top row of ports) using a mini-to-mini SAS cable.
The PERC H840 card for the R640 is installed in slot #1. This means that:
l Port 0 is on the left and port 1 is on the right on the R640.
l You must attach the cable to the R640 with the connector's blue tab on the top.
l You must attach the other end the cable to the PowerVault with the connector's blue tab
on the top.
l You know if the cable is properly connected when you hear a click as the cable locks into
place and see the green port light illuminate on the R640.
15 Install PowerVault without Encryption