Chapter 5 Trial Run and Tuning Procedure|ASDA-A&A+ Series
Revision April 2009 5-21
Table 5.B P2-31 Value “B” Setting in AutoMode (PI) and the setting of P2-00, P2-25
P2-31 value “B” Speed Loop Responsive Recommended Setting Value of P2-25
0 20Hz 13
1 30Hz 9
2 40Hz 6
3 60Hz 4
4 85Hz 3
5 120Hz 3
6 160Hz 2
7 200Hz 1
8 250Hz 1
9 and above 300Hz 0