EasyManua.ls Logo

Delta Electronics ASD-A2023MA - Automode (PI) Tuning Flowchart

Delta Electronics ASD-A2023MA
383 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Trial Run and Tuning Procedure|ASDA-A&A+ Series
5-20
Revision April 2009
5.6.4 AutoMode (PI) Tuning Flowchart
Set P2-31 to 2 (AutoMode (PI) [Continuous adjustment])
P2-31 Auto and Easy Mode Selection (Default setting is 4)
Settings:
not used
A
B
ASDA-A series:
This parameter allows the users to set the stiffness setting of easy mode and the responsiveness level
of auto-tuning mode. Users can control the stiffness and responsiveness according to application
condition. When the setting value is higher, the stiffness and the responsiveness is higher.
A: Stiffness setting of easy mode
B: Responsiveness level of auto-tuning mode
ASDA-A+ series:
This parameter allows the users to set the responsiveness level setting of auto-tuning mode. Users can
control the responsiveness according to application condition. When the setting value is higher, the
responsiveness is higher.
A: No function
B: Responsiveness level of auto-tuning mode
In AutoMode (PI), the value “B” indicates the responsiveness setting. When the setting value is higher,
the responsiveness is faster.
Adjust P2-31: Increase the setting value of P2-31. Increase the value “B” to speed the responsiveness
or reduce the noise.
Adjust P2-25: According to the setting value of P2-31 speed and adjust the responsiveness.
Continuously adjust until the satisfactory performance is achieved, and then the tuning is completed.