Chapter 5 Trial Run and Tuning Procedure|ASDA-A&A+ Series
Revision April 2009 5-23
Table 5.C P2-31 Value “B” Setting in AutoMode (PDFF) and the Speed Loop Responsiveness.
P2-31 value “B” Speed Loop Responsiveness P2-31 value “B” Speed Loop Responsiveness
0 20HZ 8 120Hz
1 30 HZ 9 140HZ
2 40 HZ A 160HZ
3 50 HZ B 180HZ
4 60 HZ C 200Hz
5 70 Hz D 220Hz
6 80Hz E 260Hz
7 100Hz F 300HZ