T
P2-29 GPE Gain Switching Condition 1280000
pulse
Kpps
r/min
P2-30
INH
Auxiliary Function
0 N/A
P2-31 AUT1
Speed Frequency Response Level in
Auto
and Semi-Auto Mode
80 Hz
P2-32▲
AUT2
Tuning Mode Selection
0 N/A
P2-33▲
INF
Semi-Auto Mode Inertia Adjustment
Sele
ction
0 N/A
P2-34 SDEV Overspeed Warning Condition 5000 r/min
P2-35 PDEV Excessive Error Warning Condition 3840000 pulse
P2-36 EDI9
External Digital Input Terminal 9
(EDI9)
0 N/A
P2-37 EDI10
External Digital Input Terminal 10
(EDI10)
0 N/A
P2-38 EDI11
External Digital Input Terminal 11
(EDI11)
0 N/A
P2-39 EDI12
External Digital Input Terminal 12
(EDI12)
0 N/A
P2-40 EDI13
External Digital Input Terminal 13
(EDI13)
0 N/A
P2-41 EDI14
External Digital Input Terminal 14
(EDI14)
0 N/A
P2-42 Reserved (Do Not Use)
P2-43 NCF2
Notch Filter 2 (Resonance
Suppressi
on)
1000 Hz
P2-44 DPH2
Notch Filter Attenuation Rate 2
(Resonan
ce Suppression)
0 dB
P2-45 DOD
Notch Filter 3 (Resonance
Suppressi
on)
1000 Hz
P2-46 FSN
Notch Filter Attenuation Rate 3
(Resonan
ce Suppression)
0 dB
P2-47 PED
Auto Resonance Suppression Mode
Sele
ction
1 N/A
P2-48 BLAS
Auto Resonance Suppression
Detection L
evel
100
N/A
P2-49 SJIT
Speed Detection Filter and Jitter
Suppressi
on
0 sec
P2-50 DCLR Pulse Deviation Clear Mode 0 N/A
P2-51 ~
P2-52
Reserved (Do Not Use)