In the web interface, go to Administration -> Firmware.
Select "Choose File" and browse to the downloaded package,
enter password and "Start Update". See below figure 6 - 3 for
a screen shot of the web interface.
Recommended firmware package is P0140.
6.5
AUTO-SYNCHRONIZE
During power-up, the power supply will check for interface
modules. Once in contact, the firmware version is checked to
verify if it is compatible with the unit. If so, nothing is noticed
of this process.
But if there is a mismatch, the interface module and the unit
will not function properly together.
Therefore the user is prompted in three different ways: via the
front panel, via Ethernet commands and via the web interface.
6.5.1 VIA FRONT PANEL
The front display will show a warning “Interface firmware
incompatible with unit. Auto-synchronize?”.
There are two options: “cancel” and “OK”.
“Cancel” allows proceeding to the normal operation, but with
the possibility that the unit and interface module don’t work
properly. The message “Update required” will be shown.
Selecting “OK” will activate an update mechanism, and the
firmware of the interface module is updated to a matching
version. No network connection is required, and no update file
has to be applied since the power supply itself contains the
matching firmware version of each type of interface module.
6.5.2 VIA ETHERNET COMMAND
To query the need of auto-synchronization, the
“SYSTEM:WARNING?” command can be send.
See the manual “Ethernet + Sequencer”.
Via Ethernet commands there is no possibility to start the
auto-synchronization.
6.5.3 VIA WEB INTERFACE
Go to “Administration, Info”. A warning is shown in case of a
firmware version mismatch.
The mismatching interface module can be auto-synchronized
by going to the related slot in “Configuration, Interfaces”.
Select “Auto synchronize” and “Apply settings” and the update
mechanism will be activated.

Other manuals for Delta Elektronika SM15K Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Elektronika SM15K Series and is the answer not in the manual?

Delta Elektronika SM15K Series Specifications

General IconGeneral
BrandDelta Elektronika
ModelSM15K Series
CategoryPower Supply
LanguageEnglish

Related product manuals