Page #162 background image
AH Motion Controller Operation Manual
7-36
_7
2. Click
(Setting) to open the setting window for the current E-CAM chart.
Master position: defines the display range of the master axis in the E-CAM curve area.
Slave position: defines the display range of the slave axis in the E-CAM curve area.
Resolution: defines the resolution of this E-CAM chart (max.: 2047)
3. You can click
(
Insert a row) or
(delete a row) to edit the Data setting area. Modifying the master/slave
position in the table ill change the E-CAM curve in the E-CAM curve area immediately.