Chapter 8  Parameters  ASDA-A2 
8-92     Revision February, 2017 
P2-02    PFG  Position Feed Forward Gain 
Address: 0204H 
0205H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: 
6.2.8 
 
Default: 
50 
 
Control 
Mode: 
PT/PR 
 
Unit: 
% 
 
Range: 
0 ~ 100 
 
Data Size: 
16-bit 
 
Format: 
Decimal 
 
Settings: 
If the position command is changed smoothly, increasing the gain 
value can reduce the position error. 
If the position command is not changed smoothly, decreasing the gain 
value can tackle the problem of mechanical vibration. 
 
P2-03    PFF 
Smooth Constant of Position Feed Forward 
Gain 
Address: 0206H 
0207H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: - 
 
Default: 
5 
 
Control 
Mode: 
PT/PR 
 
Unit: 
ms 
 
Range: 
2 ~ 100 
 
Data Size: 
16-bit 
 
Format: 
Decimal 
 
Settings: 
If the position command is changed smoothly, decreasing the value 
can reduce the position error. If the position command is not changed 
smoothly, increasing the value can tackle the problem of mechanical 
vibration.