Chapter 3  Wiring  ASDA-A2 
3-34     Revision February, 2017 
DO Signal 
Name 
Operation 
Mode 
Pin 
No. 
 
Details 
Wiring 
Method 
(Refer to 
3.4.3) 
+  - 
TPOS 
PT, PR,  
PT-S, 
PT-T, 
PR-S,  
PR-T 
1 26 
When the deviation between the motor command 
and actual position (PULSE) is smaller than the 
setting value of parameter P1-54, this DO is ON. 
C5/C6/C7/
C8 
TQL  N/A  -  -  When torque is limiting, this DO is ON. 
ALRM ALL 28 27 
When the alarm occurs (except forward/reverse 
limit, emergency stop, communication error, under 
voltage), this DO is ON. 
BRKR  ALL  -  -  Control contact of brake. 
HOME  ALL  3  2  When homing is completed, this DO is ON. 
OLW  ALL  -  -  When the overload level is reached, this DO is ON. 
WARN ALL - - 
A warning occurs. 
When it is in the status of forward/reverse limit, 
emergency stop, communication error, under 
voltage, this DO is ON. 
OVF  PT, PR  -  -  Position command /feedback overflows 
SNL (SCWL)  PR  -  -  Reverse software limit 
SPL 
(SCCWL) 
PR  -  -  Forward software limit 
Cmd_OK PR - - 
The output of internal position command is 
completed. 
CAP_OK  PR  -  -  CAPTURE procedure is completed. 
MC_OK PR - - 
When DO.Cmd_OK and TPOS are ON, this DO is 
ON. 
CAM_AREA PR  - - 
The master position of E-CAM is inside the setting 
area. 
S_CMP S, Sz - - 
When the deviation between the speed command 
and the feedback speed of the motor is smaller than 
the setting value of parameter P1-47, this DO is ON. 
SDO_0  ALL  -  -  Output the status of bit00 of P4-06 
SDO_1  ALL  -  -  Output the status of bit01 of P4-06 
SDO_2  ALL  -  -  Output the status of bit02 of P4-06 
SDO_3  ALL  -  -  Output the status of bit03 of P4-06 
SDO_4  ALL  -  -  Output the status of bit04 of P4-06 
SDO_5  ALL  -  -  Output the status of bit05 of P4-06 
SDO_6  ALL  -  -  Output the status of bit06 of P4-06 
SDO_7  ALL  -  -  Output the status of bit07 of P4-06 
SDO_8  ALL  -  -  Output the status of bit08 of P4-06