EasyManuals Logo

Delta ASD-A2 Series User Manual

Delta ASD-A2 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #331 background imageLoading...
Page #331 background image
Chapter 8 Parameters ASDA-A2
8-80 Revision February, 2017
Unit:
%
Range:
0 ~ 300
Data Size:
16-bit
Format:
Decimal
Settings:
Setup protection level (for the percentage of rated torque, set the value
to 0 means to disable the function, set the value to 1 or number above
means to enable the function)
P1-58 CRSHT Motor Crash Protection Time
Address: 0174H
0175H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
1
Control
Mode:
ALL
Unit:
ms
Range:
0 ~ 1000
Data Size:
16-bit
Format:
Decimal
Settings:
Setup the protection time:
When it reaches the level, AL.030 occurs after exceeding the
protection time.
NOTE
This function is only suitable for non-contactable application, such as
electric discharge machines. (Please setup P1-37 correctly).
P1-59 MFLT Analog Speed Command
Address: 0176H
0177H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0.0 0
Control
Mode:
S
Unit:
1 ms 0.1 ms
Range:
0.0 ~ 4.0 0 ~ 40
Data Size:
16-bit
Format:
One decimal DEC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2 Series and is the answer not in the manual?

Delta ASD-A2 Series Specifications

General IconGeneral
Control ModePosition, Speed, Torque
FeedbackIncremental encoder, Absolute encoder
Rated Output Power0.1 kW to 15 kW
Power Supply200-230V AC
Communication InterfaceRS-485, CANopen
Protection FeaturesOverload, Overvoltage, Overcurrent, Overheat

Related product manuals