ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-79
P1-55 MSPD Maximum Speed Limit
Address: 016EH
016FH
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
Same as the rated speed of each model
Control
Mode:
ALL
Unit:
r/min
Range:
0 ~ max.speed
Data Size:
16-bit
Format:
Decimal
Settings:
The default of the max. speed of servo motor is set to the rated speed.
P1-56 OVW Output Overload Warning Level
Address: 0170H
0171H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
120
Control
Mode:
ALL
Unit:
%
Range:
0 ~ 120
Data Size:
16-bit
Format:
Decimal
Settings:
The setting value is 0 ~ 100, if the servo motor continuously outputs
the load and is higher than the setting proportion (P1-56), the early
warning for overload (DO is set to 10, OLW) will occur.
If the setting value is over 100, it will disable this function.
P1-57 CRSHA Motor Crash Protection (torque percentage)
Address: 0172H
0173H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0
Control
Mode:
ALL