ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-157
P4-18 COF4
Current Detector (W2 Phase) Offset
Adjustment
Address: 0424H
0425H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
Factory default
Control
Mode:
ALL
Unit:
-
Range:
0 ~ 32767
Data Size:
16-bit
Format:
Decimal
Settings:
Manually adjust the hardware offset. The adjustment function needs to
be enabled by the setting of parameter P2-08. It is not suggested to
adjust the auxiliary adjustment. This parameter cannot be reset.
P4-19 TIGB
IGBT NTC Adjustment Detection Level
(cannot reset)
Address: 0426H
0427H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
Factory default
Control
Mode:
ALL
Unit:
-
Range:
1 ~ 4
Data Size:
16-bit
Format:
Decimal
Settings:
Please cool down the drive to 25 Celsius degree when adjusting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2 Series and is the answer not in the manual?

Delta ASD-A2 Series Specifications

General IconGeneral
Control ModePosition, Speed, Torque
FeedbackIncremental encoder, Absolute encoder
Rated Output Power0.1 kW to 15 kW
Power Supply200-230V AC
Communication InterfaceRS-485, CANopen
Protection FeaturesOverload, Overvoltage, Overcurrent, Overheat

Related product manuals