8-158 Revision February, 2017
P4-20 DOF1
Offset Adjustment Value of Analog Monitor
Output (Ch1)
Address: 0428H
0429H
Operational
Interface
Panel / Software Communication
Related Section:
6.4.4
Default
0
Control
Mode
ALL
Unit
mV
Range
-800 ~ 800
Data Size
16-bit
Format
Decimal
Settings
Offset adjustment value (cannot reset)
P4-21 DOF2
Offset Adjustment Value of Analog Monitor
Output (Ch2)
Address: 042AH
042BH
Operational
Interface
Panel / Software Communication
Related Section:
6.4.4
Default
0
Control
Mode
ALL
Unit
mV
Range
-800 ~ 800
Data Size
16-bit
Format
Decimal
Settings
Offset adjustment value (cannot reset)
P4-22 SAO Analog Speed Input OFFSET
Address: 042CH
042DH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
S
Unit
mV