Chapter 8 ParametersASDA-A2R Series
8-98 Revision December, 2014
Settings
Semi-auto Setting:
1: It means the inertia estimation in semi-auto mode is
completed. The inertia value can be accessed via P1-37.
0: 1. When the display is 0, it means the inertia adjustment is
not completed and is adjusting.
2. When the setting is 0, it means the inertia adjustment is
not completed and is adjusting.
Rotary motor uses inertia ratio for estimation; Linear motor
uses weight of linear motor and load for estimation.
P2-34 SDEV The Condition of Overspeed Warning
Address: 0244H
0245H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
5000
Control
Mode
S
Unit
Permanent magnet synchronous rotary
motor: rpm
Permanent magnet synchronous linear
motor:
3
10
m/s
Range
Permanent magnet synchronous rotary
motor: 1 ~ 5000
Permanent magnet synchronous linear
motor: 1~15999
Data Size
16bit
Format
DEC
Settings
The setting of over speed warning in servo drive error display
(P0-01)
P2-35 PDEV
Condition of Excessive Position Control
Deviation Warning
Address: 0246H
0247H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
3840000
Control
Mode
PTPR
Semi-auto setting
Reserved
Not in use

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2R-1B43 Series and is the answer not in the manual?

Delta ASD-A2R-1B43 Series Specifications

General IconGeneral
BrandDelta
ModelASD-A2R-1B43 Series
CategoryServo Drives
LanguageEnglish

Related product manuals