Chapter 8 ParametersASDA-A2R Series
8-102 Revision December, 2014
Range:
50 ~ 2000
Data Size:
16bit
Format:
DEC
Settings:
The second setting value of resonance frequency. If P2-44 is set
to 0, this function is disabled. P2-23 and P2-24 are the first Notch
filter.
P2-44 DPH2
Resonance Suppression (Notch filter)
Attenuation Rate (2)
Address: 0258H
0259H
Operational
Interface:
Panel / Software Communication
Related Section:
6.3.7
Default:
0
Control
Mode:
ALL
Unit:
dB
Range:
0 ~ 32 (0: disable Notch filter)
Data Size:
16bit
Format:
DEC
Settings:
The second resonance suppression (notch filter) attenuation rate.
When this parameter is set to 0, the function of Notch filter is
disabled.
P2-45 NCF3 Resonance Suppression (Notch filter) (3)
Address: 025AH
025BH
Operational
Interface:
Panel / Software Communication
Related Section:
6.3.7
Default:
1000
Control
Mode:
ALL
Unit:
Hz
Range:
50 ~ 2000
Data Size:
16bit
Format:
DEC
Settings:
The third group of mechanism resonance frequency setting value.
If P2-46 is set to 0, this function will be disabled. P2-23 and P2-24
are the first group of resonance suppression (Notch filter).