Chapter 2 InstallationASDA-A2R Series
2-6 Revision December, 2014
Motor Cable Selection and Installation Precautions
The selection of motor cables and installation affect the performance of EMI Filter. Please
follow the precautions mention below.
1. Use the cable that has braid shielding (The effect of double shielding is better)
2. The shield on both sides of the motor cable should be grounded in the shortest
distance and the largest contact area.
3. The protective paint of the U-shape saddle and metal plate should be removed in order
to ensure the good contact. Please see disgram 1.
4. It should have correct connection between the braid shielding of the motor cable and
the metal plate. The braid shielding on both sides of the motor cable should be fixed
by the U-shape saddle and metal plate. Please see diagram 2 for the correct
connection.
Diagram 1
Diagram 2
Remove the paint on metal saddle to ensure the good grounding
U-sha
p
e saddle
Metal plate with
good grounding