Chapter 8 ParametersASDA-A2R Series
8-150 Revision December, 2014
P5-24 AC4
Acceleration/Deceleration Time (Number
#4)
Address: 0530H
0531H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
800
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16bit
Format
DEC
Settings
Please refer to P5-20 for the setting of acceleration/deceleration
time in PR mode.
P5-25 AC5
Acceleration/Deceleration Time (Number
#5)
Address: 0532H
0533H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
900
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16bit
Format
DEC
Settings
Please refer to P5-20 for the setting of acceleration/deceleration
time in PR mode.
P5-26 AC6
Acceleration/Deceleration Time (Number
#6)
Address: 0534H
0535H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
1000
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16bit

Table of Contents