Chapter 8 ParametersASDA-A2R Series
8-276 Revision December, 2014
PM-47 Max. Current of Linear Motor
Address:
Applicable
motor type
LM
Related Section: -
Operational
Interface
Panel / Software Communication
Default
100
Unit
0.01A
Range
0 ~ the rated current of servo drive
Data Size
16bit
Format
DEC
Settings
PM-48 Max. Speed of Linear Motor
Address:
Applicable
motor type
LM
Related Section: -
Operational
Interface
Panel / Software Communication
Default
5000
Unit
3
10
m/s
Range
0~15999
Data Size
16bit
Format
DEC
Settings
PM-49 Force Constant of Linear Motor
Address:
Applicable
motor type
LM
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0
Unit
0.01N / A
Range
0~177362
Data Size
32bit