Chapter 8 ParametersASDA-A2R Series
8-276 Revision December, 2014
PM-47 Max. Current of Linear Motor
Address:
Applicable
motor type:
LM
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
100
Unit:
0.01A
Range:
0 ~ the rated current of servo drive
Data Size:
16bit
Format:
DEC
Settings:
PM-48 Max. Speed of Linear Motor
Address:
Applicable
motor type:
LM
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
5000
Unit:
3
10
m/s
Range:
0~15999
Data Size:
16bit
Format:
DEC
Settings:
PM-49 Force Constant of Linear Motor
Address:
Applicable
motor type:
LM
Related Section: -
Operational
Interface:
Panel / Software Communication
Default:
0
Unit:
0.01N / A
Range:
0~177362
Data Size:
32bit