Chapter 6  Control Modes of Operation  ASDA-B2 
6-46     Revision May, 2018 
P1-04    MON1 
Analog Monitor Output Proportion 1 
(MON1) 
Address: 0108H 
0109H 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: 
Section 6.4.4 
 
Default: 100 
 
Control 
Mode: 
ALL 
 
Unit: % (full scale) 
 
Range: 0 ~ 100 
 
Data Size: 16-bit 
 
Display 
Format: 
Decimal 
Settings: Please refer to parameter P0-03 for the setting of analog output 
selection.  
Example: P0-03 = 01 (MON1 is motor speed analog output, 
MON2 is motor torque analog output) 
 
MON1 output voltage= 8 × 
 
Motor speed 
(unit: Volts) 
(Max. motor speed × 
P1-04 
) 
100 
 
 
MON2 output voltage= 8 × 
 
Motor toque 
(unit: Volts) 
(Max. motor torque × 
P1-05 
) 
100 
 
P1-05    MON2 
MON2 Analog Monitor Output Proportion 
2  
Address: 010AH 
010BH 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: 
Section 6.4.4 
 
Default: 100 
 
Control 
Mode: 
ALL 
 
Unit: % (full scale) 
 
Range: 0 ~ 100 
 
Data Size: 16-bit 
 
Display 
Format: 
Decimal 
Settings: Please refer to parameter P0-03 for the setting of analog output 
selection. 
Example: P0-03 = 01 (MON1 is motor speed analog output,