P0-03    MON  Analog Monitor Output   
Address: 0006H 
0007H 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section:   
6.6.3 
 
Default: 00 
 
Control 
Mode: 
ALL 
 
Unit: - 
 
Range: 00 ~ 77 
 
Data Size: 16-bit 
 
Format: Hexadecimal   
 Settings:  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOTE
 
Please refer to parameter P1-04, P1-05 for proportional setting 
of analog output voltage. 
 
For example: P0-03 = 01 (MON1 is the analog output of motor 
speed; MON2 is the analog output of motor torque) 
 
MON1outputvoltage  8 
.
 (unit:Volts) 
 
MON2outputvoltage  8 
.
 (unit: Volts) 
 
P0-04■ 
 
Reserved 
Address: 0008H 
0009H 
    
 
 
MON1, 
MON2 
Setting 
Value 
Description 
0  Motor speed (+/-8 Volts/Max. speed) 
1  Motor torque (+/-8 Volts/Max. torque) 
2 
Pulse command frequency (+8 Volts/4.5Mpps) 
3 
Speed command (+/-8 Volts/ Max. speed 
command) 
4 
Torque command (+/-8 Volts/Max. torque 
command) 
5 
VBUS voltage (+/-8 Volts/450V) 
6 Reserved 
7 Reserved