ASDA-B2  Chapter 7 Parameters 
Revision May, 2018  7-5 
Position Control Parameter 
Parameter  Abbr.  Function  Default  Unit 
Control Mode 
Related 
Section 
PT  S  T 
P1-01 CTL 
Input Setting of Control Mode 
and Control Command 
0 
pulse 
r/min 
N-M 
O O O  6.1 
P1-02▲ PSTL 
Speed and Torque Limit 
Setting 
0 N/A O O O 6.6 
P1-12 ~ 
P1-14 
TQ1 ~ 3 Internal Torque Limit 1 ~ 3  100  %  O  O  O  6.4.1 
P1-46▲ GR3 
Pulse Number of Encoder 
Output 
2500 pulse O O O  - 
P1-55  MSPD  Maximum Speed Setting  rated  r/min  O  O  O  - 
P2-50  CCLR  Pulse Clear Mode  0  N/A  O      - 
External Pulse Control Command (PT mode) 
P1-00▲  PTT  External Pulse Input Type  0x2  N/A  O      6.2.1 
P1-44▲  GR1  Gear Ratio (Numerator) (N1)  1  pulse  O      6.2.3 
P1-45▲  GR2  Gear Ratio (Denominator) (M)  1  pulse  O      6.2.3 
P2-60▲  GR4  Gear Ratio (Numerator) (N2)  1  pulse  O      - 
P2-61▲  GR5  Gear Ratio (Numerator) (N3)  1  pulse  O      - 
P2-62▲  GR6  Gear Ratio (Numerator) (N4)  1  pulse  O      - 
(★)  Read-only register, e.g. parameter P0-00, P0-10 and P4-00, etc. 
(▲) 
Setting is invalid when Servo On, e.g. parameter P1-00, P1-46 and P2-33, etc. 
() 
Not effective until re-power on or off the servo drive, e.g. parameter P1-01 and 
P3-00. 
() 
Volatile parameters, e.g. parameter P2-30 and P3-06.