Chapter 9 Troubleshooting 
9.1  Alarm of Servo Drive 
Display  Alarm Name  Alarm Description 
Corresponding 
DO 
Servo 
Status 
AL001 Over current 
The current of the main circuit is 1.5 
times more than the instantaneous 
current of the motor. 
ALM 
Servo 
Off 
AL002 
Over voltage 
The voltage of the main circuit is 
higher than the standard voltage. 
ALM 
Servo 
Off 
AL003 
Under voltage 
The voltage of the main circuit is 
lower than the standard voltage. 
WARN 
Servo 
Off 
AL004 
Motor Combination 
Error 
The drive corresponds to the wrong 
motor. 
ALM 
Servo 
Off 
AL005 
Regeneration Error Regeneration control is in error.  ALM 
Servo 
Off 
AL006 
Overload  The motor and the drive is overload.  ALM 
Servo 
Off 
AL007 
Over speed 
The control speed of the motor 
exceeds the normal speed. 
ALM 
Servo 
Off 
AL008 
Abnormal Pulse 
Command 
The input frequency of the pulse 
command is over the allowable value 
of the hardware interface. 
ALM 
Servo 
Off 
AL009 
Excessive 
Deviation of 
Position Command 
The deviation of position command 
exceeds the allowable setting value. 
ALM 
Servo 
Off 
AL011 
Encoder Error 
The encoder produces abnormal 
pulse. 
ALM 
Servo 
Off 
AL012 
Adjustment Error 
When executing electrical 
adjustment, the adjusted value 
exceeds the allowable value. 
ALM 
Servo 
Off 
AL013 
Emergency Stop  Press the emergency stop button.  WARN 
Servo 
Off 
AL014 
Reverse Limit Error Activate the reverse limit switch.  WARN 
Servo 
On 
AL015 
Forward Limit Error Activate the forward limit switch.  WARN 
Servo 
On