ASDA-B2  Chapter 4  Panel Display and Operation 
Revision May, 2018     4-3 
4.3 Status Display 
4.3.1 Save Setting Display 
When finishing editing parameter, press the SET Key to save the setting. The panel will 
display the setting status according to the setting for a second. 
Display Symbol  Description 
 
The setting value is saved correctly. (Saved) 
 
Read-only parameter. Write-protected. (Read-Only) 
 
Enter the wrong password or no password has been entered. 
(Locked) 
 
Incorrect setting value or enter the reserved setting value. (Out of 
Range) 
 
No entering is allowed when it is Servo ON. (Servo On) 
 
Parameter will be effective after the servo drive is re-powered on. 
(Power On) 
4.3.2 Decimal Point 
Display Symbol  Description 
 
High byte / low byte indication: When the data is displayed in 
decimal 32 bits, it is for indicating the current high or low byte. 
Negative sign: When the data is displayed in decimal format, the 
two decimal points in the left represents the negative sign, no 
matter it is showed in 16 or 32 bits. When it is showed in 
hexadecimal format, it only shows positive sign. 
4.3.3 Alarm Message 
Display Symbol  Description 
 
When there is an error of the drive, it will show ‘AL’ as the alarm 
sign and ‘nnn’ as the alarm code. For further explanation, please 
refer to Chapter 7, P0-01, parameter description, or Chapter 9, 
Troubleshooting.