ASDA-B2  Chapter 2  Installation 
Revision May, 2018    2-11 
Motor Cable Selection and Installation Precautions 
The selection of motor cables and installation affect the performance of EMI Filter.  
Please follow the precautions mention below. 
1.  Use the cable that has braid shielding (The effect of double shielding is better) 
2.  The shield on both sides of the motor cable should be grounded in the shortest 
distance and the largest contact area. 
3.  The protective paint of the U-shape saddle and metal plate should be removed in 
order to ensure the good contact. Please see disgram 1. 
4.  It should have correct connection between the braid shielding of the motor cable and 
the metal plate. The braid shielding on both sides of the motor cable should be fixed 
by the U-shape saddle and metal plate. Please see diagram 2 for the correct 
connection.  
 
Figure 1 
 
Saddle on both ends 
 
Saddle on one end 
Figure 2