EasyManuals Logo

Delta CP2000 Series User Manual

Delta CP2000 Series
868 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #169 background imageLoading...
Page #169 background image
Chapter 7 Optional AccessoriesCP2000
7-60
460V Series
CP2000
Applicable EMC
Filter
Zero Phase Reactor
Carrier
Freq.
Conducted Emission
Radiation
Emission
Frame Model
Rated
Input
Current
[A]
Input Side
(R/S/T)
Output Side
(U/V/W)
Output Shielded
Cable Length
EN61800-3
EN618000-3 C2
D0
VFD450CP43S 91
B84143B0120R110
N/A
N/A
≤6kHz 25m
*C2
VFD550CP43S 110
D
VFD750CP43B 150
B84143B0180S020
RF300X00A
or
T60006L2160V066
*C3
VFD900CP43A 180
≤4kHz
13m
E
VFD1100CP43A 220 B84143B0250S020
C2
VFD1320CP43B 260 B84143B0320S020 B64290L0084X830
F
VFD1600CP43A 310
B84143B0400S020
VFD1850CP43B 370
G
VFD2200CP43A 460
B84143B0600S020
≤2kHz
VFD2800CP43A 530
H
VFD3150CP43A 616
B84143B1000S020 *C3
VFD3550CP43A 683
VFD4000CP43A 770
VFD5000CP43A 930
VFD5600CP43A-00 1094
B84143B1600S020
Contact Delta for more information
VFD4500CP43C-21 1094
VFD6300CP43A-00 1212
VFD6300CP43C-21 1212
*For radiated emission, the drive needs to be placed inside a cabinet.
CP2000
Applicable EMC
Filter
Zero Phase Reactor
Carrier
Freq.
Conducted Emission
Radiation
Emission
Frame Model
Rated
Input
Current
[A]
Input Side
(R/S/T)
Output Side
(U/V/W)
Output Shielded
Cable Length
EN61800-3
EN618000-3 C3
D0
VFD450CP43S 91
B84143A0120R105
N/A N/A
≤6kHz
150m
C3
VFD550CP43S 110
D
VFD750CP43B 150
B84143B0180S080 *C3
VFD900CP43A 180
≤4kHz
E
VFD1100CP43A 220 B84143B0250S080
C3
VFD1320CP43B 260 B84143B0320S080
F
VFD1600CP43A 310
B84143B0400S080
VFD1850CP43B 370
G
VFD2200CP43A 460
B84143B0600S080
VFD2800CP43A 530
H
VFD3150CP43A 616
B84143B1000S080 100m
VFD3550CP43A 683
VFD4000CP43A 770
VFD5000CP43A 930
VFD5600CP43A-00 1094
B84143B1600S080
Contact Delta for more information
VFD4500CP43C-21 1094
VFD6300CP43A-00 1212
VFD6300CP43C-21 1212
*For radiated emission, the drive needs to be placed inside a cabinet.
Table 7-72
Table 7-73

Table of Contents

Other manuals for Delta CP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta CP2000 Series and is the answer not in the manual?

Delta CP2000 Series Specifications

General IconGeneral
Output Voltage0 ~ Input Voltage
Communication InterfaceRS-485
Storage Temperature-20°C to 60°C
Input Voltage200-240V AC, 380-480V AC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit