2. Programming Concepts
2-19
Special
M
Function
ES2
EX2
EC5
SS2
SA2
SE
SX2
OFF
ON
STOP
RUN
RUN
STOP
Attrib.
Latch
-ed
Default
ON: VFD-A (Default), OFF: other models
of VFD
M1178
Enable knob VR0
OFF
-
-
R/W
NO
OFF
M1179
Enable knob VR1
OFF
-
-
R/W
NO
OFF
M1180
The EX2/SX2 model reads analog-to-
digital values immediately.
EX2
OFF - - R/W NO OFF
M1181
The EX2/SX2 model outputs digital-to-
analog values immediately.
EX2
OFF - - R/W NO OFF
M1182*
M1182 = ON, disable auto-mapping
function when connected with left-side
modules.
For SA2 /SX2/SE models, values of
AIO modules will be auto-mapped to
D9800 and above.
If the left side is connected with a
communication module, additional 10
words will be occupied. Ex: 04AD-SL
+ EN01-SL + SA2, average value of
Ch1~Ch4 of 04AD-SL maps to
D9810~D9813.
ON - - R/W NO ON
M1183*
M1183 = ON, disable auto mapping
function when connected with special
modules
#: ES2/EX2: OFF; SE/SA2/SX2: ON
(maps to D9900 and later)
ES2/
EX2
# - - R/W NO #
M1190
Set Y0 high speed output as 0.01 ~
10Hz; not available for 12SE
ES2/
EX2
OFF OFF - R/W NO OFF
M1191
Set Y1 high speed output as 0.01 ~ 10Hz;
not available for 12SE
ES2/
EX2
OFF OFF - R/W NO OFF
M1192
Set Y2 high speed output as 0.01 ~ 10Hz;
not available for 12SE
ES2/
EX2
OFF OFF - R/W NO OFF
M1193
Set Y3 high speed output as 0.01 ~ 10Hz;
not available for 12SE
ES2/
EX2
OFF OFF - R/W NO OFF
M1196
Keep connectivity flag for ETHRS
instrucitons; available for ES2-E: V1.08,
26SE: V1.0, 12SE: V1.88 or later
ES2-
E
SE
OFF OFF - R/W NO OFF
M1197
In execution flag for ETHRS instrucitons;
available for ES2-E: V1.08, 26SE: V1.0,
12SE: V1.88 or later
ES2-
E
SE
OFF OFF - R/W NO OFF
M1198
Error flag for ETHRS instrucitons;
available for ES2-E: V1.08, 26SE: V1.0,
12SE: V1.88 or later
ES2-
E
SE
OFF OFF - R/W NO OFF
M1200
C200 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1201
C201 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1202
C202 counting mode ON: count down)
OFF
-
-
R/W
NO
OFF
M1203
C203 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1204
C204 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1205
C205 counting mode (ON :count down)
OFF
-
-
R/W
NO
OFF
M1206
C206 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1207
C207 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1208
C208 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1209
C209 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1210
C210 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1211
C211 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1212
C212 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1213
C213 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1214
C214 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1215
C215 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1216
C216 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1217
C217 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1218
C218 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1219
C219 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1220
C220 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1221
C221 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF
M1222
C222 counting mode (ON: count down)
OFF
-
-
R/W
NO
OFF

Table of Contents