DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP Operation Manual - Programming
Special
M
Function
EX2
SS2
SA2
SE
SX2
Attrib.
Latch
-ed
Default
C223 counting mode (ON: count down)
○
○
○
○
C224 counting mode (ON: count down)
○
○
○
○
C225 counting mode (ON: count down)
○
○
○
○
C226 counting mode (ON: count down)
○
○
○
○
C227 counting mode (ON: count down)
○
○
○
○
C228 counting mode (ON: count down)
○
○
○
○
C229 counting mode (ON: count down)
○
○
○
○
C230 counting mode (ON: count down)
○
○
○
○
C231 counting mode (ON: count down)
○
○
○
○
M1232
C232 counting mode (ON: count down)
╳
○
╳
╳
C232 counter monitor (ON: count down)
○
╳
○
○
C233 counter monitor (ON: count down)
○
○
○
○
C234 counter monitor (ON: count down)
○
○
○
○
C235 counting mode (ON: count down)
○
○
○
○
C236 counting mode (ON: count down)
○
○
○
○
C237 counting mode (ON: count down)
○
○
○
○
C238 counting mode (ON: count down)
○
○
○
○
C239 counting mode (ON: count down)
○
○
○
○
C240 counting mode (ON: count down)
○
○
○
○
C241 counting mode (ON: count down)
○
○
○
○
C242 counting mode (ON: count down)
○
○
○
○
M1243
C243 Reset function control. ON = R
function disabled
○ ○ ○ ○
OFF - - R/W NO OFF
M1244
C244 Reset function control. ON = R
function disabled
○ ○ ○ ○
OFF - - R/W NO OFF
C245 counter monitor (ON: count down)
○
○
○
○
C246 counter monitor (ON: count down)
○
○
○
○
C247 counter monitor (ON: count down)
○
○
○
○
C248 counter monitor (ON: count down)
○
○
○
○
C249 counter monitor (ON: count down)
○
○
○
○
C250 counter monitor (ON: count down)
○
○
○
○
C251 counter monitor (ON: count down)
○
○
○
○
C252 counter monitor (ON: count down)
○
○
○
○
C253 counter monitor (ON: count down)
○
○
○
○
C254 counter monitor (ON: count down)
○
○
○
○
M1257
Set the ramp up/down of Y0, Y2 to be “S
curve.” ON = S curve.
ES2/
EX2
○ ○ ○
OFF OFF - R/W NO OFF
M1260
Set up X7 as the reset signal for software
counters C235 ~ C241
○ ○ ○ ○
OFF - - R/W NO OFF
M1262
Enable cyclic output for table output
function of DPTPO instruction. ON =
ES2/
EX2
○ ○ ○
OFF OFF - R/W NO OFF
M1263
Execute RS instruction with M1263 to set
the data receiving as completed, when
the data receiving stops for a period of
time that is longer than what D1168 was
set. Refer to RS instruction for more
○ ○ ○ ○
OFF OFF OFF R/W NO OFF
M1270
C235 counting mode (ON: falling-edge
count)
○ ○ ○ ○
OFF - - R/W NO OFF
M1271
C236 counting mode ON: falling-edge
count)
○ ○ ○ ○
OFF - - R/W NO OFF
M1272
C237 counting mode (ON: falling-edge
count)
○ ○ ○ ○
OFF - - R/W NO OFF
M1273
C238 counting mode (ON: falling-edge
count)
○ ○ ○ ○
OFF - - R/W NO OFF
M1274
C239 counting mode (ON: falling-edge
count)
○ ○ ○ ○
OFF - - R/W NO OFF
M1275
C240 counting mode (ON: falling-edge
count)
○ ○ ○ ○
OFF - - R/W NO OFF
M1276
C241 counting mode (ON: falling-edge
count)
○ ○ ○ ○
OFF - - R/W NO OFF
M1277
C242 counting mode (ON: falling-edge
count)
○ ○ ○ ○
OFF - - R/W NO OFF