3.2.2 Ground Mount (Optional)
Grounded Bracket kit is an optional part, please contact the customer service
center for the detail.
1. Ensure the grounded base to which the unit is to be mounted is sufficiently
strong enough to carry the weight.
2.
The grounded base horizontally (perpendicular to the floor), and mark required
mounting hole locations per Figure 3-13.
3. Lock the grounded brackets to foots with 8 screws. (Figure 3-12)
5. Set the inverter on the ground mounting base.
4. Secure the grounded brackets on the grounded base with 4 M10 screws per
Figure 3-13.
Figure 3-12 : Lock the grounded brackets to foots
* Screw torque required for assembling: 15 Nm