- When 30A string fuses are utilized do NOT use input 2、3、4、7、
10、14、15、16 and 19 on either MPPT channel.
CAUTION !
M125HV_111 is compatible with 1500V/30A CE listed fuse, however, the designer
must be beware of the following requirements:
• The max Isc-stc of a connected array (sum of all paralleled strings) cannot
exceed the rated Isc limit of the inverter, that is no more than 320A total.
• Because of internal current limitations and higher string currents allowable
with 30A fuses, inputs 2、3、4、7、10、14、15、16 and 19 must NOT be
used.
■ DC Side Y connection
-
01
-
02
-
03
-
04
-
05
-
06
-
07
-
08
-
09
-
10
-
11
-
12
-
13
-
14
-
15
-
16
-
17
-
18
-
19
-
20
Fuse Board
-
Fuse Board +
+01 +02 +03 +04 +05 +06 +07 +08 +09 +10 +11 +12 +13 +14 +15 +16 +17 +18 +19 +20
Switch 2 Switch 1
Recommend fuse models
1. Vendor: Mersen Vendor P/N: HP15M30
2. Vendor: EATON(Bussmann Series) Vendor P/N: PV-30A10F85L
3. Vendor: Littelfuse Vendor P/N: SPXV 30
40
Installation