INSTALLATION
15 Jun 12 3-11
HyperPoolShaker
WARNING! VIBRATOR MOTOR MUST BE OPERATED AT THE DESIGNATED
SUPPLY VOLTAGE
.
WARNING! HIGH VOLTAGE MAY BE PRESENT. BE SURE FUSED
DISCONNECT SUPPLYING ELECTRICAL POWER TO THIS EQUIPMENT IS
OPEN. LOCK OUT AND TAG OUT POWER SUPPLY TO PREVENT
ACCIDENTAL APPLICATION OF POWER WHILE MAKING ELECTRICAL
CONNECTIONS.
WARNING! ELECTRIC
AL CONNECTIONS MUST BE MADE IN ACCORDANCE
WITH THE NATIONAL ELECTRICAL CODE (NEC) AND ALL APPLICABLE
LOCAL CODES. FAILURE TO COMPLY MAY RESULT IN AN UNSAFE
CONDITION THAT COULD INJURE PERSONNEL OR DAMAGE EQUIPMENT.
ENSURE THAT ALL ELECTRICAL AND CONDUIT CO
NNECTIONS ARE
SECURE.
Figure 3-11 Electric Power Supply Connections to Input Power Strip
A fused disconnect primary power supply is required for this equipment. The fused
disconnect and interconnecting wiring to the equipment must be suitably sized and in accordance
with National Electrical Code (NEC) standards and all other applicable state and local codes.
Additional wiring requirements are as follows:
1. The fused disconnect device shall have sufficient interrupting capacity to clear the maximum
fault current capability of the power supply system.
2. The GROUND connection in the power supply junction box must be connected to a known
ground.