You become aware of abnormal performance, instability,
false signals, misplaced interference, for no apparent reason
The coil does not switch on, unlike the remote control and the headphones
44
CAUSES SOLUTIONS
Sensitivity is too high. Lower it.
You are in a zone with a lot of interference
(high-voltage power lines, electric transformer,
electric fence).
Lower the sensitivity or move to
a dierent zone.
There is a storm nearby and the electromagnetic
discharges of lightning are interfering with the detector.
You are close to other working metal detectors. Change or shift the frequency
(PG 11/12).
You switched on the detector with the coil near a metal
surface or near the stems aluminium tube (in the
folded-up position).
Switch it o, then on again with the coil
in the air and the stem fully deployed,
away from any sources of metal.
The ground balance is set too low.
In manual mode set it to 90.
The battery is discharged.
Recharge it.
The ground is heavily infested with iron and other metals.
Find a less infested place.
Don’t practice in your garden!
CAUSES SOLUTIONS
You have a dierent coil selected in the menu :
OPTION / Coil from the remote control or in the menu
COIL from the headphones.
Select the corresponding coil
(pg 24/29).
The serial number of the coil that you had entered in
the remote control was incorrect or was changed
inadvertently.
Check the coil’s serial number
(pg 24/30).
The coil battery is drained.
Recharge it.
The coil battery has reached the end of its lifespan.
Contact your reseller or XP.
The coil is defective or blocked.
Contact your reseller or XP.