98 9 November 2001 Transmitters
Setting Up Automatic
Shutdown
To set a forward transmitter and return receiver (or return
transmitter and forward receiver) in the same loop to use a
specific communication line for automatic shutdown, set
switches (see Figure 43) on each module to the same
address.
Use this procedure for the
200-TX, 700-TX, and
800-TX. Set switches SW2
and SW3 before you install
the transmitter into the shelf.
If you don’t plan to use
Automatic Shutdown, set both
switches to the 0 position.
1. Identify (from “TX Switch Settings for Automatic
Shutdown” ) the switch positions for SW2 and SW3 that
correspond to the identification number of the
communication line between the transmitter and the
return receiver.
2. Use a non-conducting alignment tool to set both SW2
and SW3 to the positions matching the line address.
TX Switch Settings for Automatic Shutdown
* Do not use line 17. This line provides a ground for shelf connection external to this
shelf and is not connected to the shutdown selector switches.
**Use line IDs 9 and 18 only when both the receiver and the transmitter are installed
in one shelf.
Connector
Pin
Line
Number
SW2
Setting
SW3
Setting
—
NO Auto
Shutdown
00
1 101
3 202
5 303
7 404
9 505
11 6 0 6
13 7 0 7
15 8 0 8
-- **9 0 9
2101 0
4112 0
6123 0
8134 0
10 14 5 0
12 15 6 0
14 16 7 0
16 (GND) *17 8 0
— **18 9 0