OPERATOR’S MANUAL
PM300, PM332, PM400 Planter Monitors
11001-1372-201702 Rev B
46 / ALARMS
SELF-TEST FAILURE
The Self Test Failure alarm activates at every power cycle comparing
configured number of rows to number of rows detected. Any sensor not
found during self-test or inaccurate configuration will sound alarm and
display on the Operate (main) screen. The alarm can be acknowledged by
pressing the Alarm Cancel key, but will re-activate until problem is
resolved.
Figure 37
Self Test Failure
HI GROUND SPEED EXCEEDED (OPTIONAL)
The Hi Ground Speed Exceeded alarm is triggered anytime the speed has
exceeded the mph input in the Ground Speed Setup screen. Alarm can be
silenced by pressing the Alarm Cancel key.
Figure 38
Maximum Speed Exceeded Warning Display (Optional)