Configuring network interfaces Configure DSL interfaces
Digi TransPor Routers User Guide
258
Configure permanent virtual circuit (PVC) parameters
ÉWeb
1. Go to Configuration > Network > Interfaces > DSL >PVC.
2. Configure PVCparameters as needed:
Enable this PVC
Check this box to enable PVC settings.
Encapsulation
The method of encapsulation to use when transporting data over this APVC. The appropriate
value can be selected from a drop list which includes the following options:
Option Description
PPPoA VC-Mux RFC 2364 VC-multiplexed PPP over AAL5
PPPoA LLC RFC 2364 LLC encapsulated PPP over AAL5
PPPoE VC-Mux RFC 2516 VC-multiplexed PPP over Ethernet
PPPoE LLC RFC 2516 LLC encapsulated PPP over Ethernet
Bridged Ethernet VC-Mux RFC 2684 VC-multiplexed bridged Ethernet
Bridged Ethernet LLC RFC 2684 LLC encapsulated bridged Ethernet
Routed IP VC-Mux RFC 1483 VC multiplexing routed IP over ATM
Routed IP LLC RFC 1483 LLC encapsulated routed IP over ATM
To use PPPoA or PPPoE encapsulation, one of the available PPP instances must first be
configured to use this APVC instance as its Layer 1 interface on the associated Configuration
> Interfaces > PPP > PPP n > Advanced page.
VPI
The Virtual Path Identifier for this APVC in the range 0-255.
VCI
The Virtual Channel Identifier for this APVC in the range 0-65535.
3. Click Apply.
Command line
Command Instance Parameter Values Equivalent web parameter
apvc 0 0-255 VPI
apvc 0 0-65535 VCI