Command reference tables Networking commands
XBee/XBee-PRO ZigBee RF Modules User Guide 158
NO Network Discovery options. Set/Read the options
value for the network discovery command. The options
bitfield value can change the behavior of the ND
(network discovery) command and/or change what
optional values are returned in any received ND
responses or API node identification frames. Options
include:
0x01 = Append DD value (to ND responses or API node
identification frames)
002 = Local device sends ND response frame when ND is
issued.
CRE 0 - 0x03 [bitfield] 0
SC Scan Channels. Set/Read the list of channels to scan.
Coordinator - Bit field list of channels to choose from
prior to starting network.
Router/End Device - Bit field list of channels that will be
scanned to find a Coordinator/Router to join.
Changes to SC should be written using WR command to
preserve the SC setting if a power cycle occurs.
Bit (Channel):
0 (0x0B) 4 (0x0F) 8 (0x13) 12 (0x17)
1 (0x0C) 5 (0x10) 9 (0x14) 13 (0x18)
2 (0x0D) 6 (0x11) 10 (0x15) 14 (0x19)
3 (0x0E) 7 (0x12) 11 (0x16) 15 (0x1A)
CRE XBee
1 - 0xFFFF [bitfield]
XBee-PRO (S2)
1 - 0x3FFF [bitfield]
(bits 14, 15 not allowed)
XBee-PRO (S2B)
1-0x7FFF
(bit 15 is not allowed)
1FFE
AT
Command
Name and Description
Node
Type
1
Parameter Range Default

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBEE2 and is the answer not in the manual?

Digi XBEE2 Specifications

General IconGeneral
BrandDigi
ModelXBEE2
CategoryControl Unit
LanguageEnglish

Related product manuals