keys to move the indicator. To choose that
item, press the Enter key. This item can not
be changed without first clearing storage
memory.
Auto Shut-off
User can set the desired time for the unit to
automatically shut-off for non-use. This time
can be set from 0 to 30 minutes. Press the
Enter key to put the unit into the Edit mode,
then use the arrow keys to select the
desired time.
Pressing the Menu key or Enter key will
take you back to the Function Menu.
Clear Storage Memory
Clear Storage Memory is the last item that
appears in the UTILITY MENU. The Clear
Storage Memory screen contains no Edit
mode. Pressing the Enter key will cause the
screen to change to:
The marker will default to NO. To move the
marker to YES, press the down arrow key.
Pressing the arrow keys repeatedly will
move the marker back and forth, from YES
to NO. To choose Clear Memory, move
marker to YES, then press ENTER. If
clearing memory is not desired, move
marker to NO and press ENTER or press
MENU key at any time. Pressing the MENU
key will exit back to the FUNCTION MENU.
IMPORTANT: WHEN CLEARING
MEMORY, ALL MEMORY SLOTS--10 IN
VACUUM FLUCTUATION FUNCTION, 60
IN PULSATOR RATIO FUNCTION, AND 30
IN MILK/REST FUNCTION, 5 IN THE
PULSATION ELECTRONIC AND 5 GRAPH
STORAGE SLOTS--WILL BE ERASED.
There is no selective erasure of individual
memory slots.
Print Limping data – Limping data can be
printed to the Digimet Printer or uploaded
to a computer by using Utility Menu item
10, Print Limping data.
DISPLAYS
Vacuum Level Function Display
The Vacuum Level Function displays
those measurement calculations as
described in the section on the Vacuum
Level Function. The display format is
depicted in the following column:
In addition to the calculated
measurements, the current Fluctuation
Time Frame setting will also be displayed
as " /1s " on the last line, where 1 second
is the current setting.
Pulsator Ratio Function Display
The Pulsator Ratio Function displays those
VACUUM LEVEL
Avg 0.00 “Hg
Max 0.00 “Hg
Min 0.00 “Hg
Fluc 0.00 / 1s
PULSATOR RATIO
A+B 60.2% 696ms
C+D 39.8% 460ms
B Fluc .33 “Hg
Max/P 13.68“Hg
Min/P 0.00“Hg
A 11.3% 131 ms
B 48.9% 565 ms
C 12.0% 139 ms
D 27.8% 321 ms
Total 1156 ms
-UTILITY MENU
10 Print
Limping data
-UTILITY MENU
9 Clear Memory
> No
Yes