42
The Pulsator Ratio Function data printout is
shown below:
PULSATOR RATIO
Location Timer
01 01:56:55
A+B 49.9% 582 msec
C+D 50.1% 584 msec
B Fluc 0.11”Hg
Max/P 12.00”Hg
Min/P 0.00”Hg
A 4.8% 56 msec
B 45.1% 526 msec
C 8.9% 104 msec
D 41.2% 480 msec
Total 1166 msec
PPM 51.4
The Milk/Rest Function printout data appears
below:
MILK/REST RATIO
Pulsator A
Location Timer
02 02:01:04
Ratio 50/50
Pulses/Min 51.8
Max/P 12.00
Min/P 0.00
Milk 50.3%
Milk 582 msec
Rest 49.7%
Rest 575 msec
LCP 6.50”Hg
Total: 1157 msec
Function heading
If no label is chosen then this
space will appear blank.
Location
Timer stamp
Function data
Function heading
Label
Location and Timer stamp
Function data