42 TMR3610 Operators Manual D4023-EN
SETTING
[display]
D.A.N.
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
WEIGH METHOD
(W MTHD)
1005
1=General
2=Fast
3=Slow
Select weigh method. The
speed the weight changes as
shown on the LCD.
1 PRESS ZERO
(1 ZERO)
1006
ON/OFF
If ON -press and hold Zero
key to Zero/Balance scale.
AUTO OFF
(AUTOFF)
1007
OFF, 15, 30, 45, 60
Indicator turns off after
selected minutes of stable
weight.
DISPLAY UNIT
(LB-KG)
1008
LB/KG
Display pounds LB or
Kilograms - KG
SCROLL DELAY
(SCROLL)
1101
0,1,2,3,4, 5, 6, 7, 8, 9
Scroll rate for cold
temperatures
0=normal 9=slowest
SAVE TARE
(SAVTAR)
1102
ON/OFF
Saves tare weight to non-
volatile memory.
PRELOAD TARE
(PRETAR)
1103
ON/OFF
Tare weights can be entered
using the numeric keypad.
TIME FORMAT
(TIME F)
1201
24 HR
AM/PM
Select time format -AM/PM or
24 hours
TIME
(TIME)
1202
HH:MM:SS, AM/PM
Enter changes HH:MM:SS
(use numeric keypad) use
function key to change
between HH:MM:SS then
choose AM/PM.
DATE FORMAT
(DATE F)
1203
1-mm-dd
2-mm/dd/yy
3-mm/dd/yyyy
4-dd-mm
5-dd/mm/yy
6-dd/mm/yyyy
7-ddmmyy
8-ddmmyyyy
Select date format
DATE
(DATE)
1204
Enter ddmmyy
Select key changes date or
numerical keys -function key
chooses DD/MM/YY.
DATE CHECK
(DT CHK)
1205
ON/OFF
Verifies the real time clock
has a valid date at power up.
REMOTE INPUT 1
(RMINP1)
1401
MIXCTR, INGRED, OFF, PRESET,
SWITCH, TARE, PRINT, HOLD,
NETGRS, M+, ZERO
Sets function of remote input
line on the power cord.
Direct Access Numbers (D.A.N.)

Table of Contents

Related product manuals