52 TMR3610 Operators Manual D4023-EN
SETTING
[display]
D.A.N.
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
RANGE TEST
(R-TEST)
6216
OFF, ON
If ON Feed-lines sent from
Data-Link are marked "done".
Valid when using Data-Link
System.
AUTO START PENS
(AUTPEN)
6217
OFF, ON
If ON -Starts Pens List after
Recipe is loaded.
FEED ZONE
(FDZONE)
6218
ALL, 1, 2, 3, 4, 5, 6, 7, 8, 9
Select feed zone for recipe
deliveries.
PARTIAL FEEDING
(PARTFD)
6219
OFF, ON
If ON Partial feedings will be
Recorded.
MIMIC TYREL
(TCI300)
6221
OFF, ON
If ON - Records preset
weights like a Tyrel TCX-
1300 Indicator.
SETUP FEATURES
SIGNON SETTING
(SIGNON)
8001
OFF, ON
Enables continuous display of
sign-on message
SIGNON MESSAGE
(SIGMSG)
8002
SIGMSG 1,2,3
Enables editing of the sign-on
message
MAINTENANCE
MESSAGE
(MANTMG)
8011
MANTMG 1, 2, 3, 4, 5, 6, 7, 8, 9,
10
Enables editing of the
maintenance message
MAINTENANCE
MESS. TIME
(MANTTM)
8012
200, Time is entered using key
pad.
Time for maintenance
message to be triggered.
DEAD WEIGHT CAL
(WT CAL)
8121
Follow instructions shown on LCD
Calibration method using
weights
TEMPERATURE
CALIBRATION
(T CALB)
8123
OFF/ON
On=Scale adjusts for
temperature changes
INDICATOR SETUP
INFO
(DS>SER)
8299
DS>SER
Downloads all setup
information to the serial port
KEYTEST
8888
Enables front panel key test
Direct Access Numbers (D.A.N.)