54 TMR3610 Operators Manual D4023-EN
SETTING
(display)
D.A.N.
NO.
OPTIONS (displayed)
BOLD=DEFAULT
DESCRIPTION
Enter the service menu is
required to use the 9000
series numbers.
NUMBER KEYPAD
ENABLED
(NUMKEY)
90051
NUMKEY, NUMOFF
If ONEnables front panel
number pad
QWERTY KEYPAD
ENABLED
(QWERTY)
90061
QTYOFF, QWERTY
If ONEnables QWERTY
style keyboard
MODEL
IDENTIFICATION
(MODELID)
90201
3610
Allow entry of specific model
ID to be display at power up.
MODEL ID TIME
(MODLTM)
90202
1, 2, 3, 4, 5, 6, 7, 8, 9, 0
If ON---Entry amount of time
for MODEL ID to be display at
power up.
CLEAR PEAK WEIGHT
(CLRPKW)
90302
NO / YES
If ONAllows clearing of
stored Peak weights
CLEAR ROTATION
COUNTER
(CLRREV)
90303
NO / YES
Allow clearing of stored
rotation counts
CLEAR HOUR METER
(CLRHRS)
90304
NO / YES
Allows clearing of hour meter
MAINTENANCE
MESS. CLEAR
(MANCLR)
90305
0
Allows for clearing of
maintenance message time
or entry of new time.
REINITIALIZE
(REINIT)
99999
NO / YES
Reset indicator to factory
default settings. 3
GAIN CALIBRATION
(GN CAL)
100001
Starts Calibration Timer
Enters gain calibration
Direct Access Numbers (D.A.N.)