EasyManua.ls Logo

Dimplex EDL170-520RF - 8 Maintenance - Error Codes; 8.8 Error Message Codes

Dimplex EDL170-520RF
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error Messages
26
Display Error Probable causes Solutions
Temporary operation
measures while
waiting for problem
to be solved
MEMO/
BUS
• Electronic board defect.
• Bus wire defect.
• Display screen defect.
• Voltage too high on
electrical network.
• Cabling error during
electrical connection
(connection to electricity
provider or moisture
sensor...).
• Damage during
transportation.
• Replace main electronics
board or;
• Replace display screen
board.
• Appliance non-func-
tional.
T_AIR
• Air temperature sensor
defect (Temperature of
air taken in).
• Sensor not functioning.
• Sensor unplugged from
board.
• Sensor cable damaged.
• Replace sensor.
• Heat pump
non-functional.
• Electrical backup
heats
water to 43°C (min
38°C).
T_DE-
FROST
• Evaporator sensor
defect (de-icing
temperature).
• Sensor not functioning.
• Sensor unplugged from
board.
• Sensor cable damaged.
• Replace sensor.
• Heat pump
non-functional.
• Electrical backup
heats
water to 43°C (min
38°C).
T_water
• Tank water sensor
defect.
• Sensor not functioning.
• Sensor unplugged from
board.
• Sensor cable damaged.
• Replace sensor.
• Heat pump
non-functional.
Clock • Clock/timer defect.
• Voltage too high on
electrical network.
• Damage during
transportation.
• 1-Press «clock settings»
and set date and time.
• 2-If the error message
still does not disappear,
replace the electronics
board.
• Programmed heating
periods are no longer
valid: the water is
maintained continu-
ously
at the standard set
temperature (if no
signal
or control is connected
to the «external con-
trol»
switch).
OVER
PRESS.
• Heat pump pressure
too
high.
• No water in tank.
• Water is too hot (>75°C)
• Water sensor removed
from tank.
• Defective water sensor.
• Check that the tank has

water and purged of air.
• Change the water sensor
• Check that the water
sensor is in the right
position in the tank.
• Heat pump is
non-functional.
• Resets automatically.
• Authorised to run on
backup.
FREQ.
DEFRO
• De-icing too often.

• Air inlet / outlet blocked.
• Ventilation duct blocked.
• Air duct is too long or has
too many elbows.
• Evaporator clogged.
• Check that air is
circulating properly
throughout the piping
circuit.
• Check pipe lengths.

ducts.
• Check evaporator is
clean.
• Heat pump
non-functional.
• Electrical backup
heats
water to 43°C (min
38°C).
LOW
PRES
• Heat pump pressure
too low.

• Air inlet / outlet blocked.
• Ventilation duct blocked.
• Fan blocked or out of
order.
• Evaporator clogged.
• Ice on evaporator.
• Check the fan is working.
• Check that air is
circulating properly
throughout the piping
circuit.
• Check pipe lengths

ducts.
• Check evaporator is
clean.
W
• Heat pump
non-functional.
• Electrical backup
heats
water to 43°C (min
38°C).
8.8 Error Message Codes: Errors, Solutions and Operating in case of Error
 

Table of Contents

Related product manuals