Controls
19
E When the battery power is less than
20%, the system will display low
battery alarm and limit the high speed.
when ”F606 low battery normal
working” function is turn on, the
system will no longer limit the
function, until the battery power is
less than 10%, the system will limit
functions.
F When the temperature of hydraulic oil
is too low, the normal function of the
machine will be affected. Turn ”F607
Hydraulic preheat” function on, the
hydraulic pump will automatically
work for 3 minutes, the machine is
not allowed to operate during the
pump working.
G It returns back to main interface,
when the button is
depressed.
NOTE:The modification of transport
mode would be invalid at the moment
of one of the following being activated.
Platform control is chosen.
The degree of chassis inclining
exceeds 5.
The angle of main boom lifting
exceeds 20.
Main boom extends more than
one meter.
exit button
MENU button
5 Basket signal bypass selector
To enable movements from the control
panel on the ground with the red
emergency button pressed from the
platform, keep the selector enabled
together with the enable key activated and
the movement selectors concerned.
6 Engine start-up button
Not used.
7 Acoustic warning button
To activate the acoustic signal press the
yellow button.
8 Key-operated switch
With the key in position 0 the truck is
switched off: in another position, if brought
to 0 the electric circuit closes, switching off
the truck.
To activate the controls on the ground,
turn the key-operated switch to the icon
representing the truck. To activate the
controls in the platform, turn the
key-operated switch to the position
representing the platform.
9 Turret rotation selector
To rotate the turret counter clockwise, turn
the selector to the LH.
To rotate the turret clockwise, turn the
selector to the RH.
10 Primary telescopic boom lift selector
To lift the primary telescopic boom, move
the selector forwards.
To lower the primary boom, move the
selector backwards.
11 Primary telescopic boom extension
selector
To extend the primary boom, turn the
selector to the LH.
To retract the primary boom, turn the
selector to the RH.
12 Red indicator light
The red indicator lights up in condition of
the truck being dangerous or in case of
the truck being in mechanical faulty.
(together with the specific signal)
In this situation, stop the vehicle after
lowering the platform and check the