3.2.4 Restore factory setting
Press RST button for about 7 seconds, then gateway will be rebooted and restored to factory setting.
3.3 Local Maintenance through Console Port
To ensure easy maintenance, the DWG2000 device provides a standard RS232 console port, which has a Baud
rate of 115200bps. Users can log in the device to carry out maintenance-related configurations through the
console port.
Example: Log in DWG2000 via Console Port
Step 1: Prepare a serial cable as follows (standard RS232, 115200bps);
Step 2: Connect the F port of the serial cable with the COM port of PC. If the PC does not have a COM
port, please use a USB-to-COM converting tool to connect the serial cable with the PC.
Step 3: Connect the M port of the serial cable with the console port of the DWG2000 device.
Step 4: Conduct configurations on login software.
Herein we take the PuTTY sofeware as an example. Detailed configurations are as follows:
After finishing the above configurations, click the Open button to enter the maintenance interface of the