K
Kelly DeanSep 6, 2025
What does Directed 403.NISS4HT 2.39 RSR Automobile Accessories start fail mean?
- BbarreraphilipSep 6, 2025
The RXT start/stop message was received by the module, but not executed on the vehicle.
What does Directed 403.NISS4HT 2.39 RSR Automobile Accessories start fail mean?
The RXT start/stop message was received by the module, but not executed on the vehicle.
What does Directed Automobile Accessories stop fail mean?
The RXT start/stop message was received by the module, but not executed on the vehicle.
Why is my Directed 403.NISS4HT 2.39 RSR module not getting power?
First, ensure the D2D harness is properly connected and verify that 12 Volts are present between the red and black wires. If the voltage is correct and the Directed Automobile Accessories module still has no power, it may be defective.
What to do if my Directed 403.NISS4HT 2.39 RSR system says 'Bypass data not detected'?
Check the connection of the bypass line. If multiple wires are used, make sure they are not inverted. Also, ensure the vehicle still operates correctly using the factory key.
What to do if my Directed 403.NISS4HT 2.39 RSR Automobile Accessories system shows 'CAN1 not detected'?
Check the connections of the CAN1 Tan and Tan/Black wires. Then, wake up the data bus by turning the ignition on and try again. If your installation does not require this connection for Directed Automobile Accessories, skip this step by pressing the programming button 5 times.
What to do if my Directed 403.NISS4HT 2.39 RSR Automobile Accessories system shows 'CAN2 not detected'?
Check the connections of the CAN2 Orange/Green and Orange/Brown wires. Wake up the data bus by turning the ignition on and try again. If your Directed Automobile Accessories installation does not require this connection, skip this step by pressing the programming button 5 times.
What to do if my Directed Automobile Accessories system shows 'J1850 not detected'?
Check the J1850 wire connection. Wake up the data bus by turning the ignition on and try again.
What to do if my Directed 403.NISS4HT 2.39 RSR system displays 'Bypass processing error'?
The bypass calculation failed. Reset the Directed Automobile Accessories module and try again. If the condition persists, please contact Technical Support.
What does it mean when my Directed 403.NISS4HT 2.39 RSR says 'Waiting to begin the programming sequence'?
This indicates that you should ensure the correct programming procedure is being followed for your Directed Automobile Accessories system.
What to do if my Directed 403.NISS4HT 2.39 RSR Automobile Accessories system says 'Initialization failed'?
Reset the Directed Automobile Accessories module and complete the programming again. If the issue persists, please contact Technical Support.