SK3000 Operator’s Manual Maintenance - 89
Procedures
Platform Switch
Adjust if auxiliary controls do not operate properly
when stepping on platform.
If control does not stay engaged when standing
on platform:
1. Loosen two screws (1).
2. Tilt switch (2) up and tighten screws.
3. Stand on platform and turn ignition switch.
4. Ensure auxiliary control(s) stay engaged.
5. Repeat steps 1-4 if needed.
If control does not return to neutral when operator steps off platform:
1. Loosen two screws (1).
2. Tilt switch (2) down and tighten screws.
3. Stand on platform and turn ignition switch.
4. Operate auxiliary control(s) and step off platform. Control should return to neutral within two
seconds.
5. Repeat steps 1-4 if needed.